Quantitative measurement of 219Rn radioactivity in exhaled breath from patients with bone metastasis of castration-resistant prostate cancer treated with 223RaCl2

Abstract

Background

The α-emitting radionuclide radium-223 (223Ra) is widely used for the treatment of bone metastasis in patients with castration-resistant prostate cancer. However, 223Ra decays into radon-219 (219Rn) which is a noble-gas isotope, and 219Rn may escape from patients treated with 223Ra via their respiration. In this study, we quantified the amount of 219Rn contained in the breath of patients treated with 223Ra to estimate its effect on the internal exposure dose of caregivers.

Methods

A total of 12 breath samples were collected using a breath collection bag from a total of six patients treated with 223RaCl2. Approximately 300 mL of exhaled breath was collected in a breath bag at 1 min and at 5 min after the start of 223RaCl2 administration. The contents of each bag were measured using an HPGe detector, and the amount of 219Rn was quantified based on the detection of the γ peak of 211Bi, which is a descendant nuclide of 219Rn, persisting in the breath bag. The effective dose to caregivers arising from the inhalation of 219Rn was estimated by referring to the scenario for the calculation of release criteria established for 131I therapy in Japan.

Results

A small peak for the 351-keV γ ray of 211Bi originating from the exhalation of 219Rn was observed. Using the observed γ peak of 211Bi, the average amounts of 219Rn per unit breath volume at 1 min and 5 min after the start of 223RaCl2 administration were calculated as 90 ± 56 Bq/mL and 28 ± 9 Bq/mL, respectively. The effective dose of 219Rn to caregivers was estimated to be 3.5 μSv per injection.

Conclusions

The amount of 219Rn in the exhaled breath of patients treated with 223RaCl2 was quantitatively calculated using breath collection bags. The internal radiation exposure of caregivers from 219Rn in the exhaled breath of patients treated with 223RaCl2 is relatively small.

Background

Recently, radium-223 (223Ra) dichloride (223RaCl2; Xofigo®) has been widely used for the treatment of bone metastases in patients with castration-resistant prostate cancer (CRPC) [1, 2]. This radionuclide emits α-particles within a short range in tissues and with a high linear energy transfer, making it suitable for the treatment of cancer cells with minimal side effects in the surrounding tissues. As shown in the decay chain of 223Ra (Fig. 1), some descendant nuclides of 223Ra also emit α-particles and contribute to its killing effect on cancer cells. However, 223Ra decays into radon-219 (219Rn) which is an isotope of a noble-gas element, and this 219Rn may escape from patients treated with 223Ra. Although the escape of 219Rn from patients is probably minor because of the very short half-life of 219Rn (3.96 s), the amount of 219Rn escaping from patients should be quantified to allow the internal radiation exposure experienced by medical staff and caregivers to be estimated. Yamamoto et al. mentioned that 219Rn may escape via the respiration of patients and reported that the concentration of the descendant nuclides of 219Rn in a room increased during radionuclide therapy with 223Ra, compared with that without the patients [3]. However, the amount of 219Rn exhaled through the respiration of patients has not been quantified in a hospital setting. In this study, the breath of patients treated with 223Ra was collected using a breath collection bag and the 219Rn radioactivity was quantified by measuring the γ rays of 211Bi, which is a descendant nuclide of 219Rn, persisting in the breath bag. The purpose of this study was to evaluate the level of 219Rn radioactivity in the exhaled breath of patients treated with 223Ra to enable a precise estimation of the internal radiation exposure dose experienced by caregivers.

Fig. 1
figure 1

Main decay chain of 223Ra

Methods

Measurement of expired gas from patients

The study protocol was approved by the institutional review board of Osaka University Hospital. First, we investigated whether the breath of the patients contains radionuclides emitting α-particles using an α survey meter (Hitachi TCS-232b, Tokyo, Japan). A patient (body weight 55.0 kg) received 223RaCl2 of 3.0 MBq (55 kBq/kg) for the treatment of bone metastases from CRPC. After informed consent was obtained from the patient, the α survey meter was placed closely to the mouth of the patient from the start of 223RaCl2 administration, and α-particles in the breath of the patient were directly measured until 3 min after the start of administration. Additionally, the count rate at 5 min after the start of administration was also measured.

Then, a total of 12 breath samples were collected using breath collection bags (Otsuka Pharmaceutical, Tokyo, Japan) from a total of six patients (71.3 ± 5.4 years old, body weight 59.5 ± 11.7 kg) received 223RaCl2 (3.4 ± 0.8 MBq). The administration of 223RaCl2 to the patients was conducted slowly over a period of approximately 1 min. After informed consent was obtained from each patient, approximately 300 mL of exhaled breath was collected into a breath bag at 1 min and at 5 min after the start of 223RaCl2 administration. A breath sampling time of 1 min after the start of administration was selected because the amount of 219Rn contained in a patient’s breath is expected to reach a peak value at this time because of the slow administration of 223RaCl2 (see also Fig. 3 which is the result of the direct measurement of the breath of the patient by the α survey meter). A sampling time of 5 min is expected to correspond to the time at which the patient is likely to leave the injection room. After sampling, the breath sample was removed from the bag using a syringe (volume 50 mL, minimum volume scale 1 mL) to enable the bag to be folded into a small, fixed geometric shape (see also Fig. 2) for measurement using a high-purity germanium (HPGe) detector (Canberra BE-2020, Connecticut, USA). The volume of the breath collected in the bag was measured using the volume scale printed on the syringe (the uncertainty for the measured volume of the breath sample was estimated to be several milliliters). Because 219Rn and its descendant nuclides may escape from the bag during the use of the syringe, the bag was allowed to stand for more than 80 s until almost all the 219Rn atoms in the breath bag had decayed into non-volatile descendant nuclides prior to the removal of the breath sample. Then, the breath sample was removed through a glass-fiber filter (ADVANTEC GB-100R, Tokyo, Japan) attached to the syringe to catch the descendant nuclides of 219Rn. After the removal of the breath sample, the breath bag, together with the glass-fiber filter, was subjected to γ-ray spectrometry using an HPGe detector for 1800 s at almost zero distance. The amount of 219Rn in the breath sample was estimated as follows. Based on the observed γ peak of 211Bi (351 keV), the radioactivity of 211Pb in transient radioactive equilibrium with 211Bi was calculated [4]. Then, from the 211Pb radioactivity at the end of the breath collection, the amount of 219Rn contained in the breath sample was estimated assuming that the number of 211Pb atoms at the end of the breath collection would be equivalent to that of 219Rn because of the very short half-life of 219Rn. The measurement efficiency for the 351-keV γ peak of 211Bi at the same distance with the measurement of the breath bag was evaluated based on the measurement of a self-produced 223Ra point source, the radioactivity of which was determined using a 133Ba standard source. The measurement efficiency was determined to be 2.63 ± 0.13%. The uncertainty for the efficiency is including the uncertainty of the radioactivity of the 133Ba standard source (4.8%) and counting errors for the measurements of the 133Ba standard source and the 223Ra point source (less than 1%).

Fig. 2
figure 2

Photographs of a the breath bag with the glass-fiber filter after the removal of the breath sample and b the folded breath bag for the measurement with an HPGe detector

Estimation of radiation exposure experienced by medical staff

The descendant nuclides of 219Rn exhaled through the breath of patients may float through the air by attaching to dust or aerosol particles. These nuclides can contribute to medical staff and caregivers being exposed to radiation internally. Therefore, we also investigated whether the inhalation of descendant nuclides of 219Rn can be blocked by the use of a mask. Medical staff wore an N95 mask (3M 1870+, Tokyo, Japan) during the administration of 223Ra to the patients. After administration, the outside and inside (face side) of the mask were measured using an α survey meter (Hitachi TCS-232b, Tokyo, Japan). A total of five masks worn by medical staff who stood close to the patients during 223RaCl2 therapy were measured during two injections (three medical staff for one injection [administration dose 3.9 MBq] and two staff for the other [administration dose: 3.0 MBq]). The measurements using the survey meter were conducted while placing the survey meter in close contact with the surface of each mask, and the count rate was recorded at 2 min after the start of measurement with a time constant of 30 s.

Estimation of radiation exposure experienced by caregivers

The radiation exposure experienced by caregivers was calculated based on documentation regarding the calculation of release criteria established for 131I therapy by the Ministry of Health and Welfare in Japan [5]. The blood concentration of 223Ra immediately after injection (CRa) was estimated using the following formula:

$$ {C}_{\mathrm{Ra}}=\frac{A_{\mathrm{injection}}}{V_{\mathrm{blood}}}, $$

where Ainjection is the injection dose of 223Ra and Vblood the blood volume in the human body. In this calculation, we used Ainjection = 3.4 × 103 kBq which is the average injection dose in this study and Vblood = 5.0 × 103 mL, and CRa was estimated to be 0.68 kBq/mL. The area under the curve (AUC) for the blood concentration of 223Ra was obtained using the clinical trial data (phase I) for 223RaCl2 published in Japan by the Pharmaceutical and Medical Devices Agency (PMDA) (https://www.pmda.go.jp). Duration (T), which corresponds to the AUC up to 72 h post injection (0.674 kBq·h/mL) with the assumption that the blood concentration level immediately after the injection of 223Ra is maintained, was calculated using the following equation:

$$ T=\frac{\mathrm{AUC}}{C_{\mathrm{Ra}}}, $$

and T was estimated to be 0.99 h. The concentration of 219Rn in the exhaled breath was assumed to be proportional to the blood concentration of 223Ra. The total exhaled amount of 219Rn was calculated by multiplying the radioactivity in the exhaled breath immediately after the injection by a factor of 0.99 h, assuming that the respiration rate was 12 breaths per minute and the volume of breath was 500 mL per single respiration. The effective dose coefficient for the inhalation of 219Rn was calculated as 7.9 × 10−9 mSv/Bq, with reference to the 222Rn data (6.5 × 10−6 mSv/Bq) [6] corrected by the effective half-life. Regarding the exposure scenario for caregivers, the volume of the room containing the patient was estimated to be 30 m3, air changes were regarded as once per hour, the daily respiration rate of the caregivers was estimated to be 20 m3, and the caregiver was assumed to always be present in the same room as the patient based on the release criteria for 131I in Japan [5]. To estimate the internal exposure dose experienced by caregivers, an exposure factor of 0.5 was applied [7].

Results

The time activity curve obtained in the direct measurement of α-particles in the breath of the patient by the α survey meter is shown in Fig. 3. The count rate of α-particles exceeded the measurable range (more than 100 kcpm) at several tens of seconds after the start of administration and then gradually decreased to 20 kcpm until 5 min after the start of administration, showing that radionuclides emitting α-particle were exhaled through the respiration.

Fig. 3
figure 3

Time activity curve obtained in direct measurement of α-particles in breath of patient by an α survey meter from the start of 223RaCl2 administration. The count rate exceeded the measurable range (100 kcpm) at several tens of seconds after the start of administration

A typical γ-ray spectra obtained for the measurement of a breath bag is shown in Fig. 4 a. A small peak for the 351-keV γ ray of 211Bi was observed. On the other hand, no γ peak of 269 keV from 223Ra was observed. The 351-keV peak disappeared approximately 4 h after the collection of the breath sample, as shown in Fig. 4 b. This finding unambiguously shows that the breath samples from patients treated with 223RaCl2 did not contain 223Ra.

Fig. 4
figure 4

Typical γ-ray spectrum obtained for breath bag measurements using an HPGe detector. Administration dose, 3.8 MBq; breath sampling time, 5 min after the start of administration; measurement start, a 17 min and b approximately 4 h after the end of breath collection

The amount of 219Rn contained in the breath samples as determined using γ-ray spectrometry is summarized in Table 1, together with the administration dose of 223Ra and the volume of collected breath. The amount of 219Rn exhaled in the breath at 1 min after the start of administration varied widely from 14 to 59 kBq, while the amount of 219Rn at 5 min after the start of administration was around 10 kBq. The mean value of 219Rn per unit volume of breath is shown in Fig. 5. The values were calculated as 90 ± 56 Bq/mL and 28 ± 9 Bq/mL (mean ± standard deviation) at 1 min and 5 min after the start of administration, respectively.

Table 1 Summary of the amounts of 219Rn contained in breath samples from patients treated with 223RaCl2
Fig. 5
figure 5

Mean value of 219Rn per unit volume of exhaled breath at 1 min and 5 min after the start of 223RaCl2 administration

The results of the mask measurements using the α survey meter are summarized in Table 2. Small count rates of less than 100 cpm for α-particles were detected on the outside of the masks. On the other hand, no α-particles were detected on the inside of the masks. The count rate on the outside of the masks varied widely depending on the medical staff, and the measurement for one mask showed no detection of α-particles even on the outside of the mask.

Table 2 Summary of measurement results obtained using an α survey meter for N95 masks worn by medical staff

The cumulative amount of exhaled 219Rn from the patient via exhaled breath until 72 h after the start of administration (ARn,cumulative) was calculated as follows:

$$ {A}_{\mathrm{Rn},\mathrm{cumulative}}={A}_{\mathrm{Rn},\mathrm{breath}}\times {V}_{\mathrm{breath}}\times {N}_{\mathrm{respiration}}\times T, $$

where ARn, breath is the amount of 219Rn contained in the unit volume of exhaled breath, Vbreath the volume of breath per single respiration (500 mL/respiration), Nrespiration the respiration rate per min (12 respiration/min) and T the duration with the assumption that the blood concentration level immediately after the injection of 223Ra is maintained (0.99 h). Using 90 ± 56 Bq/mL as ARn,breath, which is the amount of 219Rn contained in the breath at 1 min after the start of administration, ARn,cumulative was calculated as 32 MBq. By referring to the release criteria for patients treated with 131I, the amount of 219Rn inhaled by caregivers (ARn,inhaled) was estimated using the following formula:

$$ {A}_{\mathrm{Rn},\mathrm{inhaled}}={A}_{\mathrm{Rn},\mathrm{cumulative}}\times \frac{V_{\mathrm{daily}}}{V_{\mathrm{room}}\times {N}_{\mathrm{air}\ \mathrm{change}}}, $$

where Vdaily is the daily respiration rate of the caregivers (20 m3/d), Vroom the volume of the room containing the patient (30 m3) and Nair change the air changes per hour (1/h); ARn,inhaled was calculated as 0.89 MBq. The effective dose of 219Rn to caregivers (Deff) was estimated as follows:

$$ {D}_{\mathrm{eff}}={A}_{\mathrm{Rn},\mathrm{inhaled}}\times E\times F, $$

where E is the effective dose coefficient for the inhalation of 219Rn (7.9 × 10−9 mSv/Bq) and F the exposure factor (0.5 [7]); Deff was estimated to be 3.5 μSv per injection.

Discussion

This study showed that the amount of 219Rn contained in the breath of patients can be quantitatively measured using an HPGe detector based on the detection of the γ peak of the descendant nuclide 211Bi and a breath collection bag. In addition, the internal radiation exposure of caregivers from 219Rn was estimated to be as small as 3.5 μSv per injection. The high count rate of α-particles observed in the direct measurement of the breath of the patient by the α survey meter would be attributed to 219Rn, not to the descendant nuclides of 219Rn, exhaled through the respiration because the average radioactivity of 211Bi measured using the HPGe detector was in the order of 10 Bq and the count rate of α-particles from 211Bi in the measurement with α survey meter would be quite low compared with that from 219Rn (in the order of 10 kBq). Although the high count rate of α-particles from 219Rn exhaled through the respiration was observed using the α survey meter, the quantitative measurement of the descendant nuclide of 219Rn using the HPGe detector in this study clearly shows that the effective dose of 219Rn to caregivers is small. The amount of 219Rn contained in the breath of a patient at 1 min after the start of administration varied widely, as is shown in Table 1. The reason for this variation can be attributed to the peak shift in the exhalation of 219Rn from the breath of patients caused by the manual administration of 223RaCl2.

Since the effective dose coefficient for inhaled 219Rn has not been reported, the value for 219Rn was estimated based on the effective dose coefficient of 222Rn (6.5 × 10−6 mSv/Bq) [6]. α-Particles emitted from the descendant nuclides are thought to be the main contributors to the effective dose coefficient because their radiation weighting factor is very high compared with those of electrons and γ rays. Since the descendant nuclides of 219Rn would decay before clearance because of their short half-lives, analogous to those of 222Rn [8], and the total α-particle energy from the descendant nuclides of 219Rn would be roughly the same as that of 222Rn, the effective dose coefficient of 219Rn can be estimated by correcting the effective dose coefficient of 222Rn with its effective half-life. Using the biological half-life of 55 min for Rn [9] (effective half-lives of 3.95 s for 219Rn and 54.5 min for 222Rn), the effective dose coefficient of 219Rn was estimated to be 7.9 × 10−9 mSv/Bq (= 6.5 × 10−6 mSv/Bq × 3.95 s/54.5 min).

For the mask measurements, the observed α-particles were considered to have originated from 211Bi, which was in transient radioactive equilibrium with a 211Pb parent (half-life 36.1 min) because the half-life of 219Rn is very short. The N95 mask was capable of catching the descendant nuclides of 219Rn, that had attached to dust or aerosol particles, on the surface of the mask, but it was not thought to be capable of blocking the inhalation of 219Rn. If 219Rn had passed through the N95 mask, α-particles from the descendant nuclides of 219Rn that had decayed during and after passing through the mask would have been detectable on the inside of the mask. However, α-particles were not detected on the inside of the masks in the present study. Therefore, 219Rn is considered to have not reached the mouths of the medical staff. The reason for the variation in the count rate observed for measurements made for the outside of the masks, as shown in Table 2, is probably due to the change in the amounts of 219Rn and its descendant nuclides reaching the medical staff via the airflow in the injection room. The radioactivity of 211Bi caught by the mask, as calculated based on the measured count rate of α-particles, is expected to correspond to less than 10 Bq at the measurement start time using the instrument efficiency of 35.1%/2π written in the calibration certificate of the survey meter and an α branch of 99.724% for 211Bi. Although the radioactivity of the descendant nuclides of 219Rn caught by the mask was relatively small, wearing the N95 mask appeared to protect the internal exposure of the medical staff.

The effective dose from the inhalation of 219Rn experienced by caregivers was estimated to be 3.5 μSv per patient injection. This value is significantly lower than the dose of 5 mSv per episode for caregivers recommended by the International Commission on Radiological Protection (ICRP) [10, 11]; therefore, the internal radiation exposure from 219Rn should not affect the release criteria for patients who have been treated with 223RaCl2 in Japan.

Conclusions

The amount of 219Rn contained in the breath of patients treated with 223Ra was determined using γ-ray spectrometry with an HPGe detector and breath collection bags. Although a small peak for γ rays of 211Bi originating from 219Rn contained in the breath was observed, the estimated internal radiation exposure to caregivers via the inhalation of 219Rn was small and should not affect the release criteria of patients who have been treated with 223RaCl2.

Availability of data and materials

The datasets generated during and/or analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

AUC:

Area under the curve

CRPC:

Castration-resistant prostate cancer

HP:

High purity

ICRP:

International Commission on Radiological Protection

PMDA:

Pharmaceutical and Medical Devices Agency

References

  1. Hosono M, Ikebuchi H, Nakamura Y, Yanagida S, Kinuya S. Introduction of the targeted alpha therapy (with radium-223) into clinical practice in Japan: learnings and implementation. Ann Nucl Med. 2018; https://doi.org/10.1007/s12149-018-1317-1.

    Article  Google Scholar 

  2. Dauer LT, Williamson MJ, Humm J, O’Donoghue J, Ghani R, Awadallah R, et al. Radiation safety considerations for the use of 223RaCl2 de in men with castration-resistant prostate cancer. Health Phys. 2014;106:494–504.

    Article  CAS  Google Scholar 

  3. Yamamoto S, Kato K, Fujita N, Yamashita M, Nishimoto T, Kameyama H, et al. Detection of alpha radionuclides in air from patients during Ra-223 alpha radionuclide therapy. Sci Rep. 2018;8:10976.

    Article  Google Scholar 

  4. Henriksen G, Fisher DR, Roeske JC, Bruland ØS, Larsen RH. Targeting of osseous sites with α-emitting 223Ra: comparison with the β-emitter 89Sr in mice. J Nucl Med. 2003;44:252–9.

    CAS  PubMed  Google Scholar 

  5. Documentation regarding the calculation of release criteria for patients administered radiopharmaceutical agents: Safety Measures Division, Medication Safety Bureau, Ministry of Health and Welfare (Japanese Ministry); 1998.

  6. The fifth announcement from Science and Technology Agency (Japanese Ministry) about the amount of radioisotopes and others. (2000).

  7. Hosono M, Ikebuchi H, Nakamura Y, Yanagida S, Kinuya S. Introduction of the targeted alpha therapy (with radium-223) into clinical practice in Japan: learnings and implementation. Ann Nucl Med. 2019;33:211–21.

    Article  Google Scholar 

  8. ICRP. Lung cancer risk from radon and progeny and statement on radon. ICRP Publication 115. Ann. ICRP. 2010;40:1.

    Google Scholar 

  9. Gosink TA, Baskaran M, Holleman DF. Radon in the human body from drinking water. Health Phys. 1990;59:919–24.

    Article  CAS  Google Scholar 

  10. ICRP. The 2007 Recommendations of the International Commission on Radiological Protection. ICRP Publication 103. Ann ICRP. 2007;37:2–4.

    Google Scholar 

  11. ICRP. Radiological Protection in Medicine. ICRP Publication 105. Ann ICRP. 2007;37:6.

    Google Scholar 

Download references

Acknowledgements

We would like to thank Yoshihide Nakamura, Japan Radioisotope Association, for his excellent technical supervision. We also thank Atsushi Toyoshima, Institute for Radiation Sciences, Osaka University, for his useful comments on the article. Finally, we are grateful to Kazuya Yamaguchi and Shuuhei Kawaguchi, Osaka University Hospital, for their support on the breath collection and the measurement.

Funding

This study was funded by a radiation safety regulation research strategic promotion project from the Nuclear Regulation Authority, Japan.

Author information

Authors and Affiliations

Authors

Contributions

KO, TW, and TK contributed the study design and conducted the study. KO drafted the manuscript. TW, MH, and JH contributed the revise of the manuscript. TY, AS, and JH were the supervisors of the study. All authors read and approved the final manuscript

Corresponding author

Correspondence to Kazuhiro Ooe.

Ethics declarations

Ethics approval and consent to participate

The study protocol was approved by the institutional review board of Osaka University Hospital.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ooe, K., Watabe, T., Kamiya, T. et al. Quantitative measurement of 219Rn radioactivity in exhaled breath from patients with bone metastasis of castration-resistant prostate cancer treated with 223RaCl2. EJNMMI Phys 6, 13 (2019). https://doi.org/10.1186/s40658-019-0249-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s40658-019-0249-8

Keywords