Skip to main content
  • Original research
  • Open access
  • Published:

Patient-specific dosimetry of 99mTc-HYNIC-Tyr3-Octreotide in children

Abstract

Background

Technetium-99m-hydrazinonicotinamide-Tyr3-octreotide (99mTc-HYNIC-TOC) is recognized as a promising radiopharmaceutical for diagnosing neuroendocrine tumors (NETs). However, 99mTc-HYNIC-TOC dosimetry has been investigated only for adults. As pediatric radionuclide therapies become increasingly common, similar dosimetric studies for children are urgently needed. The aim of this study is to report personalized image-based biodistributions and dosimetry evaluations for children studies performed using 99mTc-HYNIC-TOC and to compare them with those from adult subjects.

Eleven children/teenage patients with suspected or diagnosed NETs were enrolled. Patient imaging included a series of 2–3 whole-body planar scans and SPECT/CT performed over 2–24 h after the 99mTc-HYNIC-TOC injections. The time-integrated activity coefficients (TIACs) were obtained from the hybrid planar/SPECT technique. Patient-specific doses were calculated using both the voxel-level and the organ-level approaches. Estimated children doses were compared with adults’ dosimetry.

Results

Pathologic uptake was observed in five patients. TIACs for normal organs with significant uptakes, i.e., kidneys, spleen, and liver, were similar to adults’ TIACs. Using the voxel-level approach, the average organ doses for children were 0.024 ± 0.009, 0.032 ± 0.017, and 0.017 ± 0.007 mGy/MBq for the kidneys, spleen, and liver, respectively, which were 30% larger than adults’ doses. Similar values were obtained from the organ-level dosimetry when using OLINDA with adapted organ masses. Tumor doses were 0.010–0.024 mGy/MBq. However, cross-organ contributions were much larger in children than in adults, comprising about 15–40% of the total organ/tumor doses. No statistical differences were found between mean doses and dose distributions in patients with and without pathologic uptakes.

Conclusion

Although the children TIACs were similar to those in adults, their doses were about 30% higher. No significant correlation was found between the children’s doses and their ages. However, substantial inter-patient variability in radiotracer uptake, indicating disparity in expression of somatostatin receptor between different patients, emphasizes the importance and necessity of patient-specific dosimetry for clinical studies.

Background

Somatostatin receptor scintigraphy (SSRS) has been identified as an efficient diagnostic technique for localizing and staging neuroendocrine tumors (NETs) which overexpress somatostatin receptors [1, 2]. The benefits of using SPECT and PET for diagnostic imaging of NETs are already well recognized. Currently, the most popular tracers used for NETs diagnosis are 99mTc-hydrazinonicotinamide-Tyr3-octreotide (99mTc-HYNIC-TOC) and 111In-diethylenetriaminepentaacetic acid (DTPA)-octreotide for SPECT [1, 3, 4] and 68Ga-DOTA-conjugated peptides for PET [5,6,7,8,9]. Although PET/CT imaging using 68Ga-DOTA-conjugated peptides has been shown to have high diagnostic accuracy and low radiation exposure [10, 11], limited availability of PET cameras worldwide may restrict its clinical use. On the other hand, SPECT, and also planar scintigraphy, remain the most popular nuclear medicine imaging techniques. Considering the SPECT tracers mentioned above, 99mTc-HYNIC-TOC results in better image quality and lower radiation dose than 111In-labeled pharmaceuticals [10, 12, 13]. Additionally, 99mTc-HYNIC-TOC can be obtained using a simple, single-vial kit formulation [14] which makes it especially advantageous for use in centers with limited resources [15]. Finally, labeling with technetium makes this tracer more readily available and less expensive than tracers labeled with 68Ga.

The incidence of NETs is rather low in the adult population and even lower in children. Recently, however, its rate is steadily increasing [16,17,18]. The SSRS studies are often used not only for the initial diagnosis and localization of the disease, but also for the therapy follow-up or diagnosis of the disease recurrence. Hence, information about radiation exposure, be it due to single administration or to repeated procedures, is very important, especially in children.

Since 99mTc-HYNIC-TOC diagnostic studies provide information about this radiotracer uptake and biodistribution, evaluation of its uptake in organs at risk (OAR) can predict potential toxicities. At the same time, this information may be used in radionuclide therapy planning, because its uptake in tumors is proportional to the intensity of somatostatin receptor expression in tumor cells, thus it may indicate potential effectiveness of the treatment.

Additionally, using the theranostic approach, the dose calculated for diagnostic isotope can be used to predict that which will be delivered when the diagnostic agent is replaced by the therapeutic one, (labeled with a beta-emitting radioisotope). These considerations will apply to the 99mTc-HYNIC-TOC imaging studies. Quantification of its uptake and biodistribution in tumors and OARs can be used in 99mTc-HYNIC-TOC dosimetry calculations and at the next stage to predict doses which will be delivered by peptide receptor therapy agents such as DOTA-TATE or DOTA-TOC labeled with 177Lu or 90Y. Although this procedure involves pharmaceuticals which are not identical, recent studies comparing pre-therapy biodistributions of 99mTc-HYNIC-TOC and 68Ge-DOTA-TATE with that of post-therapy of 177Lu-DOTA-octreotate support the validity of this approach [15].

Currently, only limited radiation dosimetry information is available for 99mTc-HYNIC-TOC. The earliest dosimetry study, published in 2006 by Gonzalez-Vazquez et al., determined absorbed radiation doses for eight patients using a two-dimensional dosimetry protocol based on five whole-body scans [19]. In 2011, our group reported patient-specific dosimetry calculations for 99mTc-HYNIC-TOC based on a larger study of 28 subjects [20]. A hybrid imaging protocol, including single SPECT/CT combined with a series of whole-body planar scans was used. Additionally, a 3D Monte Carlo dose estimation has been published by Momennezhad et al. in 2016 [21].

All of these dosimetry studies were done only for adults. However, the absorbed dose estimates are especially important for children [18, 22]. This is because children have an increased risk of potential adverse health effects due to their higher sensitivity to radiation and longer life expectancy resulting in increased opportunity for experiencing radiation-related cancers or cardiovascular and other non-cancer diseases [23]. Additionally, due to their smaller body sizes and potential differences in radiotracer uptakes, dosimetry calculations performed for adult subjects may not be appropriate for children. Finally, when considering the adult population, multiple studies have shown significant dose differences between individual subjects [20]. Thus, similar patient-specific dosimetry studies are needed for children.

For these reasons, the importance of dosimetry for pediatric radionuclide diagnostic and therapeutic procedures [24, 25] and also for CT imaging [26] cannot be underestimated. Currently, however, pediatric dosimetry calculations are limited to only a few child models (OLINDA software allows only for dosimetry calculation for newborn, 5, 10, and 15 years old) [27, 28].

The objective of the present study is to improve this situation. To this end, we applied the same methods as were used in our personalized image-based dosimetry determination for 99mTc-HYNIC-TOC imaging studies in adult subjects, to process and analyze 12 datasets from children’s studies. A hybrid planar/SPECT technique was employed to estimate the cumulated activities and biodistributions [20]. Both voxel-level (voxel-S) and organ-level dosimetry approaches were used to evaluate tumors’ and normal organs’ doses. Comparison between children doses and those estimated for adults [20] was performed.

Methods

Patient studies

Eleven children/teenage patients (ages 2–17 years, 4 males and 7 females) with suspected or diagnosed NETs were enrolled into this investigation, and a total of twelve imaging studies were performed. Table 1 lists these patients’ demographic information. All the patient imaging studies were performed at the Nuclear Medicine Department, Pomeranian Medical University, Szczecin, Poland.

Table 1 Demographic information of children patients involved in this study, sorted by age

The injected activities ranged from 320 to 940 MBq. For each patient, a series of two or three whole-body planar scans and a single SPECT/CT scan were performed within the 24-h time period after the injection. The majority of studies used a dual-head Infinia Hawkeye4 camera (GE Healthcare), while three whole-body planar scans were performed using a Nucline X-Ring/R camera (Mediso Medical Imaging Systems). For the SPECT/CT scans, 60 projections with 20 s/projection acquisition time were collected over the 360° non-circular orbit. The projection matrices of SPECT scans were 128 × 128 with 4.418-mm pixel size, while the matrices used for planar scans were 256 × 1024 with 2.21-mm pixel size or 512 × 1024 with 2.88-mm pixel size. A low-dose CT was used to generate attenuation maps. Additionally, for one patient, a 30-min dynamic scan was performed to study pharmacokinetics of the radiopharmaceutical uptake phase.

SPECT image reconstruction and quantification

SPECT images were reconstructed using the camera software with iterative ordered-subsets expectation maximization algorithm (OSEM) with 2 iterations and 10 subsets. The CT-based attenuation correction and Hann filter were included in the reconstruction. Although no scatter correction was applied, the attenuation map was rescaled to the broad beam values which indirectly corrected for scatter.

In order to achieve accurate image quantification, camera calibration, necessary to convert counts in the reconstructed image to activity, was performed using a point source and a planar acquisition. A 3-mL vial filled with 4.82 MBq of 99mTc was placed in air centrally between the two detectors. The camera sensitivity factor was determined by averaging the value from the two detectors.

Pharmacokinetics calculations

For use in dosimetry calculations based on the hybrid planar/SPECT approach, first, the time-activity curves (TACs) for all organs with significant uptakes (kidneys, liver, spleen) and tumors were determined from a series of whole-body (WB) planar scans. The following segmentation method was used. For each of these organs/tumors, an oversized region of interest (ROI) was manually drawn in the first WB image (acquired < 3 h after injection). A threshold set at 50% of a maximum pixel count in this ROI was then used to create a smaller 2D ROI50. Subsequently, this 2D ROI50 was registered to the entire sequence of the WB scans. Additionally, in order to perform geometrically based background subtraction [20, 29], a small ROI in the background region adjacent to each investigated organ was drawn. For each ROI50, the TAC was generated by plotting the background corrected mean-counts in this 2D ROI50 versus scan-time (hours after injection) and then fitting a mono-exponential curve to this data. From this procedure, the organ and tumor TACs, expressed in relative units of counts per hour, were obtained. Then, the effective and biological half-lives for each organ were determined.

At the next stage, the time-integrated activity coefficients (TIACs) were generated by rescaling these TACs using absolute organ activities obtained from the quantitatively reconstructed SPECT/CT images. For each organ and tumor, our dual iterative adaptive thresholding method [20, 30] was used to determine this organ/tumor volume and activity. This method uses a series of phantom experiments to generate two calibration curves. They provide the optimal thresholds, one for determining the true volume and the other for determining the true activity of the hot object placed in a warm background, as a function of the observed signal-to-background ratio of this object. The value of the threshold depends on the image reconstruction method, thus it indirectly accounts for partial volume effects and, for objects larger than 12 mL, has been shown to not depend on the object size [30]. An example of kidney segmentation using the dual iterative adaptive thresholding method is shown in Fig. 1.

Fig. 1
figure 1

An example of the right kidney segmentation based on dual iterative thresholding method in SPECT (a) and CT (b). The activity threshold was set to 25% (yellow line), and the volume threshold was equal to 36% (red line)

Dosimetry calculations

For each investigated organ and tumor, its mean dose and dose distribution (represented by the cumulated dose-volume histograms—DVHs) were estimated using the voxel-S approach. Similar to our previous dosimetry study of adult patients, the analysis of images and the dose calculations were performed using our in-house developed dosimetry software JADA [31]. The matrices of voxel-S value were pre-calculated with the EGSnr DOSXYZnrc Monte Carlo program. The voxel array corresponded to a 215 × 215 × 215 grid with voxel size of 4.418 mm, which was large enough for estimation of the cross-organ dose exchange between all the ROIs. More details about this approach can be found in [32]. Using this method, both self- and cross-organ doses were studied.

In parallel, the OLINDA 1.1 [28] dosimetry software was employed for organ-level dosimetry. The TIACs for the main organs, i.e., kidneys, liver, and spleen, were determined using the JADA software, whereas TIACs for the urinary bladder contents were calculated using the voiding bladder model provided by OLINDA. Additionally, the TIACs for the remainder of the body were estimated by subtracting all TIACs of the investigated organs from those corresponding to the whole body. Since OLINDA 1.1 provides only models for children 1, 5, 10, and 15 years old, for each of our patients, the calculations were performed using the model which was closest to his/her age. Organ-level dosimetry obtained from OLINDA with and without adjusted organ masses from patients’ SPECT/CT images were studied. The doses for tumors were estimated based on the OLINDA spherical model.

Finally, the dose estimated using the two methods described above were compared with each other and with the adult doses derived from our previous study [20]. Furthermore, the relationship between the children’s doses and their ages was analyzed.

Results

TIAC and effective half-life

In patient imaging studies, six tumors were discovered in five of the patients, as shown in Table 1. Fig. 2 displays examples of the whole-body images acquired within 3 h after injection from three of the patients who had visible tumors. The locations of tumors are indicated by arrows in this figure. The main uptake organs were the kidneys, liver, and spleen.

Fig. 2
figure 2

Whole-body planar images acquired at approximately 1.5–2.5 h after injection, with pathologic uptake indicated by arrows. Patient #1: a large tumor with low uptake located in the mediastinum; patient #7: two tumors, one located in the pancreatic head and the other in the lymph node on the left side; patient #11: a single tumor located at the center of the patient’s body (insulinoma head of pancreas)

The time-activity data for the left and right kidneys, the liver, and the spleen are displayed in Fig. 3 together with the curves corresponding to the mono-exponential fit to this data. The mean effective and biological half-lives determined from these time-activity curves are summarized in Table 2 for normal organs and tumors. Furthermore, the relationship between these TIACs and the ages of the patients are depicted in Fig. 4. The mean values of the children’s TIACs for the analyzed organs and tumors, together with the adults’ TIACs, are summarized in Table 3. Please note that all the data shown in Tables 2, 3, and 4 correspond to the average value ± standard deviation; the ranges of these average values are shown in parentheses.

Fig. 3
figure 3

Organ time-activity curves based on mono-exponential fittings for all of the patients. Different symbols correspond to different patients

Table 2 Effective and biological half-lives determined from the mono-exponential fits to the data of radiotracer uptakes in organs and lesions in children patients
Fig. 4
figure 4

Organ and tumor TIACs displayed versus patient age. Symbols represent different organs and tumors, including the left and right kidneys, liver, spleen, and tumor

Table 3 Comparison of organ TIAC for children to those for adults
Table 4 Comparison of absorbed doses in organs and tumors in children and adults

In order to investigate the uptake phase of 99mTc-HYNIC-TOC pharmacokinetics, a 30-min dynamic planar scan with a total of 60 time frames was performed for one patient. For the plotting of the changes of tracer uptake versus time, a threshold of 50% of the maximum pixel counts in each region was applied to each time frame and the counts were summed in the segmented regions. The resulting curves are shown in Fig. 5.

Fig. 5
figure 5

Time-activity curves showing radiotracer uptake in the kidneys, liver, and spleen. The data were obtained from a 30-min dynamic planar scan

Absorbed doses

Figure 6 displays the absorbed doses in children’s organs and tumors estimated using the voxel-S approach (by convolving voxel-S matrices with the activity distributions) and the organ-level method (from OLINDA software with/without adapted organ masses). The mean doses are summarized and compared with the adults’ dosimetry in Table 4. Fig. 7 displays the percent contributions of self- and cross-organ doses to the total organ and tumor doses for children patients, calculated using the voxel-S approach. Additionally, dose distributions, in terms of the cumulated DVHs, are presented in Fig. 8.

Fig. 6
figure 6

Absorbed doses in the organs and tumors calculated using the voxel-S approach, the OLINDA with adapted organ masses and OLINDA with default organ masses displayed versus patient age

Fig. 7
figure 7

Average percent contributions of self- and cross-organ doses to the total organ and tumor doses for children patients, calculated using voxel-S approach. Error bars represent standard deviations estimated from all patients’ data

Fig. 8
figure 8

Dose-volume histograms (DVHs) for normal organs and tumors. Each line represents a different patient; the lines with symbols represents the patients with pathologic uptakes

Discussion

In this study, the investigation of the biodistribution of 99mTc-HYNIC-TOC in children patients and the corresponding dosimetry calculations were performed and compared with those of adults. The study employed the hybrid planar/SPECT imaging technique. The main radiopharmaceutical uptake occurred in the kidneys, liver, and spleen. Although in our previous adult study some thyroid uptake was observed [20], no significant uptake was found in the children (shown in Fig. 2).

The TACs and TIACs determined for the kidneys, liver, and spleen are shown in Fig. 3 and Table 3. The average values of organ TIACs were 0.37 ± 0.08, 0.56 ± 0.21, and 0.43 ± 0.15 for the kidneys, liver, and spleen, respectively. The children’s TIACs for the kidneys and spleens were very similar to those obtained in the adult’s study, while TIACs for the livers in children patients were smaller than those in adults [20].

Dynamics of the radiotracer uptake was investigated in one of the patients. The analysis of this temporal behavior, displayed in Fig. 5, showed maximum uptake for the kidneys at about 7–10 min, while faster maximum uptake happened, at about 1–3 min, for both the liver and spleen. After reaching their maximum uptake, a washout phase was observed for both the kidneys and livers. However, for the spleen, after a rapid decrease following the peak uptake, a gradually increasing uptake seemed to continue beyond the time covered by this 30-min dynamic scan. This could explain the negative biological half-lives found in four of the patients, as indicated in Table 2.

Considering dosimetry for normal organs, as shown in Table 4 and Fig. 6, no significant differences were found between voxel-level dosimetry and organ-level dosimetry when using adapted organ masses in OLINDA for the kidneys and livers. On the other hand, the voxel-level doses for the spleen were slightly lower than organ-based doses. However, for all the normal organs, large discrepancies could be observed between voxel-level doses and those calculated using OLINDA without adapting organ masses. This indicates that dosimetry using OLINDA with default organ masses, especially for children models, may not reflect their true absorbed doses.

The tumor doses (shown in Table 4, Fig. 6, and Fig. 7) from the spherical model obtained using OLINDA were approximately equal to only half of the voxel-level tumor doses. This discrepancy is related to the fact that the spherical model only allows for calculation of the self-tumor doses; however, for tumors located close to the organs with large uptakes (like the kidneys, liver, or spleen), the cross-organ contributions may be substantial. This effect can be especially pronounced in small children, where distances between organs are smaller than in adults. It is more important in dose estimates for photons, because they deposit their energy at distances larger than, for example, beta particles, whose dose depositions are more localized.

When comparing children dosimetry to that for adults (listed in Table 4), organ doses for children were found to be up to 30% higher than those for adults, due to smaller organ sizes. This effect is related to the fact that, as already noted, the children’s and adults’ TIACs were similar, while the absorbed doses are inversely proportional to the organ masses. However, the tumor doses for children were lower than those for adults. Additionally, as shown in Fig. 7, children’s cross-organ contributions were equal to about 15–40% of the total organ and tumor doses, while for adults, the cross-organ doses were less than 15% of the total doses (see Fig. 3a in [32]).

Furthermore, no statistical correlation was noted between TIACs (Fig. 4), the absorbed doses (Fig. 6), and the age of children (please note, however, this statement is based on the analysis of a small sample of only 11 patients). Similarly, no statistical differences were found between mean doses and dose distributions (represented by DVHs) in patients with and without pathologic uptakes. However, large inter-patient variability was clearly observed (Fig. 6 and Fig. 8), which emphasizes the importance of performing patient-specific dosimetry in clinical studies.

Conclusions

In this study, we report the results of biodistribution analysis and dosimetry calculations for children who had 99mTc-HYNIC-TOC injections for the diagnosis of neuroendocrine tumors. The absorbed doses in children were slightly higher than those in adults. No significant correlation was found between the children’s doses and their ages. However, substantial inter-patient variability in radiotracer uptake, potentially indicating disparity in expression of somatostatin receptors between different patients, emphasizes the importance and necessity of patient-specific dosimetry in future clinical studies.

Abbreviations

99mTc-HYNIC-TOC:

Technetium-99m-hydrazinonicotinamide-Tyr3-octreotide

DVH:

Dose-volume histogram

NET:

Neuroendocrine tumor

OAR:

Organs at risk

OSEM:

Ordered-subsets expectation maximization

ROI:

Region of interest

SSRS:

Somatostatin receptor scintigraphy

TAC:

Time-activity curve

TIAC:

Time-integrated activity coefficient

WB:

Whole-body

References

  1. Gabriel M, Decristoforo C, Donnemiller E, Ulmer H, Rychlinski CW, Mather SJ, et al. An intrapatient comparison of 99mTc-EDDA/diagnosis of somatostatin receptor—expressing tumors. J Nucl Med. 2003;44:708–16.

    CAS  PubMed  Google Scholar 

  2. Reubi JC, Waser B, Schaer JC, Laissue JA. Somatostatin receptor sst1-sst5 expression in normal and neoplastic human tissues using receptor autoradiography with subtype-selective ligands. Eur J Nucl Med. 2001;28:836–46.

    Article  CAS  PubMed  Google Scholar 

  3. Czepczyński R, Parisella MG, Kosowicz J, Mikołajczak R, Ziemnicka K, Gryczyńska M, et al. Somatostatin receptor scintigraphy using 99mTc-EDDA/HYNIC-TOC in patients with medullary thyroid carcinoma. Eur J Nucl Med Mol Imaging. 2007;34:1635–45.

    Article  PubMed  Google Scholar 

  4. Rodrigues M, Traub-Weidinger T, Li S, Ibi B, Virgolini I. Comparison of 111In-DOTA-DPhe1-Tyr3-octreotide and 111In-DOTA-lanreotide scintigraphy and dosimetry in patients with neuroendocrine tumours. Eur J Nucl Med Mol Imaging. 2006;33:532–40.

    Article  PubMed  Google Scholar 

  5. Deppen SA, Liu E, Blume JD, Clanton J, Shi C, Jones-Jackson LB, et al. Safety and efficacy of 68Ga-DOTATATE PET/CT for diagnosis, staging and treatment management of neuroendocrine tumors. J Nucl Med. 2016;57:708–15.

    Article  PubMed  PubMed Central  Google Scholar 

  6. Herrmann K, Czernin J, Wolin EM, Gupta P, Barrio M, Gutierrez A, et al. Impact of 68Ga-DOTATATE PET/CT on the management of neuroendocrine tumors: the referring physician’s perspective. J Nucl Med. 2015;56:70–5.

    Article  CAS  PubMed  Google Scholar 

  7. Hope TA, Pampaloni MH, Flavell RR, Nakakura EK, Bergsland EK. Somatostatin receptor PET/MRI for the evaluation of neuroendocrine tumors. Clin Transl Imaging Springer Milan. 2017;5:63–9.

    Article  Google Scholar 

  8. Kaewput C, Vinjamuri S. Comparison of renal uptake of 68Ga-DOTANOC PET/CT and estimated glomerular filtration rate before and after peptide receptor radionuclide therapy in patients with metastatic neuroendocrine tumours. Nucl Med Commun. 2016;37:1325–32.

  9. Putzer D, Kroiss A, Waitz D, Gabriel M, Traub-Weidinger T, Uprimny C, et al. Somatostatin receptor PET in neuroendocrine tumours: 68Ga- DOTA0, Tyr3-octreotide versus 68Ga-DOTA 0-lanreotide. Eur J Nucl Med Mol Imaging. 2013;40:364–72.

    Article  CAS  PubMed  Google Scholar 

  10. Etchebehere ECSDC, de Oliveira SA, Gumz B, Vicente A, Hoff PG, Corradi G, et al. 68Ga-DOTATATE PET/CT, 99mTc-HYNIC-octreotide SPECT/CT, and whole-body MR imaging in detection of neuroendocrine tumors: a prospective trial. J Nucl Med. 2014;55:1598–604.

    Article  PubMed  Google Scholar 

  11. Kalsy N, Vinjamuri S. Should we stop offering indium-111 octreotide scans in favour of gallium-68 PET-CT scans in the UK? Nucl Med Commun. 2016;37:1221–2.

    Article  PubMed  Google Scholar 

  12. Płachcińska A, Mikołajczak R, Maecke HR, Młodkowska E, Kunert-Radek J, Michalski A, et al. Clinical usefulness of 99mTc-EDDA/HYNIC-TOC scintigraphy in oncological diagnostics: a preliminary communication. Eur J Nucl Med Mol Imaging. 2003;30:1402–6.

    Article  PubMed  Google Scholar 

  13. Sager S, Kabasakal L, Ocak M, Maecke H, Uslu L, Halac M, et al. Clinical value of technetium-99m-labeled octreotide scintigraphy in local recurrent or metastatic medullary thyroid cancers: a comparison of lesions with 18F-FDG-PET and MIBI images. Nucl Med Commun. 2013;34:1190–5.

    CAS  PubMed  PubMed Central  Google Scholar 

  14. Von Guggenberg E, Mikolajczak R, Janota B, Riccabona G, Decristoforo C. Radiopharmaceutical development of a freeze-dried kit formulation for the preparation of [99mTc-EDDA-HYNIC-D-Phe1, Tyr 3]-octreotide, a somatostatin analog for tumor diagnosis. J Pharm Sci. 2004;93:2497–506.

    Article  CAS  Google Scholar 

  15. Basu S, Kand P, Mallia M, Korde A, Shimpi H. Gratifying clinical experience with an indigenously formulated single-vial lyophilized HYNIC-TOC kit at the radiopharmaceutical division of BARC: a pivotal boost for building up a peptide receptor radionuclide therapy programme in an Indian setting. Eur J Nucl Med Mol Imaging. 2013;40:1622–4.

    Article  PubMed  Google Scholar 

  16. Öberg K, Knigge U, Kwekkeboom D, Perren A. Neuroendocrine gastro-entero-pancreatic tumors: ESMO clinical practice guidelines for diagnosis, treatment and follow-up. Ann Oncol. 2012;23

  17. Dasari A, Shen C, Halperin D, Zhao B, Zhou S, Xu Y, et al. Trends in the incidence, prevalence, and survival outcomes in patients with neuroendocrine tumors in the United States. JAMA Oncol. 2017;26:2124–30.

    Google Scholar 

  18. Pérez-Albert P, Rojas T De, Lendínez MÁ, Illade L, Andión M, Madero L. Management and outcome of children with neuroendocrine tumors of the appendix in Spain: is there room for improvement? Clin Transl Oncol. 2017;19:1168–72.

  19. González-Vázquez A, Ferro-Flores G, Arteaga de Murphy C, Gutiérrez-García Z. Biokinetics and dosimetry in patients of 99mTc-EDDA/HYNIC-Tyr3-octreotide prepared from lyophilized kits. Appl Radiat Isot. 2006;64:792–7.

    Article  PubMed  Google Scholar 

  20. Grimes J, Celler A, Birkenfeld B, Shcherbinin S, Listewnik MH, Piwowarska-Bilska H, et al. Patient-specific radiation dosimetry of 99mTc-HYNIC-Tyr3-Octreotide in neuroendocrine tumors. J Nucl Med. 2011;52:1474–81.

    Article  CAS  PubMed  Google Scholar 

  21. Momennezhad M, Nasseri S, Zakavi S, Parach A, Ghorbani M, Asl R. A 3D Monte Carlo method for estimation of patient-specific internal organs absorbed dose for 99mTc-hynic-Tyr3 -octreotide imaging. World J Nucl Med. 2016;15:114.

    Article  PubMed  PubMed Central  Google Scholar 

  22. Allan B, Davis J, Perez E, Lew J, Sola J. Malignant neuroendocrine tumors: incidence and outcomes in pediatric patients. Eur J Pediatr Surg. 2013;23:394–9.

    Article  PubMed  Google Scholar 

  23. Kamiya K, Ozasa K, Akiba S, Niwa O, Kodama K, Takamura N, et al. Long-term effects of radiation exposure on health. Lancet Elsevier Ltd. 2015;386:469–78.

    Article  CAS  Google Scholar 

  24. Jacobs F, Thierens H, Piepsz A, Bacher K, Van De Wiele C, Ham H, et al. Optimised tracer-dependent dosage cards to obtain weight-independent effective doses. Eur J Nucl Med Mol Imaging. 2005;32:581–8.

    Article  CAS  PubMed  Google Scholar 

  25. Johnson TN. Modelling approaches to dose estimation in children. Br J Clin Pharmacol. 2005;59:663–9.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  26. Gao Y, Quinn B, Mahmood U, Long D, Erdi Y, St. Germain J, et al. A comparison of pediatric and adult CT organ dose estimation methods. BMC Med. Imaging. BMC Med Imaging; 2017;17:28.

  27. Cristy M, Eckerman K. Specific absorbed fractions of energy at various ages from internal photons sources. Oak Ridge: Oak Ridge National Laboratory; 1987. p. V1–V7. ORNL/TM-8381.

  28. Stabin MG, Sparks RB, Crowe E. OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine. J Nucl Med. 2005;46:1023–7.

    PubMed  Google Scholar 

  29. Siegel JA, Thomas SR, Stubbs JB, Stabin MG, Hays MT, Koral KF, et al. MIRD pamphlet no. 16: techniques for quantitative radiopharmaceutical biodistribution data acquisition and analysis for use in human radiation dose estimates. J Nucl Med. 1999;40:37S–61S.

    CAS  PubMed  Google Scholar 

  30. Grimes J, Celler A, Shcherbinin S, Piwowarska-bilska H, Birkenfeld B. The accuracy and reproducibility of SPECT target volumes and activities estimated using an iterative adaptive thresholding technique. Nucl Medi Commun. 2012;33:1254–66.

    Article  Google Scholar 

  31. Grimes J, Uribe C, Celler A. JADA: a graphical user interface for comprehensive internal dose assessment in nuclear medicine. Med Phys. 2013;40:72501.

    Article  Google Scholar 

  32. Grimes J, Celler A. Comparison of internal dose estimates obtained using organ-level, voxel S value, and Monte Carlo techniques. Med Phys. 2014;41:92501.

    Article  Google Scholar 

Download references

Acknowledgements

This study was partly supported by the NSERC grant (194512-12).

Funding

This study was partly supported by funds from the Natural Sciences and Engineering Research Council of Canada (NSERC) Discovery Grant (194512-12).

Availability of data and materials

Patient imaging was done in the scope of the routine clinical diagnostic studies, and the data are stored (following the standard protocol) at the Nuclear Medicine Department, Pomeranian Medical University, Szczecin, Poland.

Author information

Authors and Affiliations

Authors

Contributions

All authors, XH, BB, HP-B, and AC, contributed to the design of this work. Drs. BB and HP-B were responsible for patient recruitment, imaging studies, and interpretation of images. Drs. XH and AC analyzed the data, performed dosimetry calculations, and wrote the manuscript. None of the authors have any competing interests in the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Anna Celler.

Ethics declarations

Ethics approval and consent to participate

For all patients, this 99mTc-HYNIC-TOC study was part of their diagnostic routine for primary and metastatic lesion localization, staging, or follow-up, with the final diagnosis based on the histopathologic examination. Subsequently, these patients’ data were anonymized and used to perform dosimetry calculations, with no impact on their treatment. Ethics approval for such use of anonymized patient data has been obtained.

Consent for publication

All authors read the manuscript and consented for its publication.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Hou, X., Birkenfeld, B., Piwowarska-Bilska, H. et al. Patient-specific dosimetry of 99mTc-HYNIC-Tyr3-Octreotide in children. EJNMMI Phys 4, 24 (2017). https://doi.org/10.1186/s40658-017-0191-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s40658-017-0191-6

Keywords