From: Bone marrow dosimetry in low volume mHSPC patients receiving Lu-177-PSMA therapy using SPECT/CT

Fig. 5

Bland Altman analysis for comparison of different imaging-based bone marrow dosimetry protocols. Black dotted lines represent the bias (average of the differences), red dotted lines represent the 95% limits of agreement. A Comparison between the use of 10 and 3 vertebrae for a 5-time point protocol; B Comparison between the use of a 5 time point protocol and 2 time point protocol using 10 vertebrae; C Comparison between the use of a 5 time point protocol and 2 time point protocol using 3 vertebrae; D Comparison between the use of a 5 time point protocol using 10 vertebrae (full protocol) and a 2 time point protocol using 3 vertebrae (simplified protocol)