Skip to main content

Table 4 Examples of patient weight-based personalization of optimal activity and scan time

From: Personalization of 99mTc-sestamibi activity in SPECT/CT myocardial perfusion imaging with the cardiofocal SmartZoom® collimator

Patient weight, kg

Personalized activity using a fixed scan time (20 s per projection angle, using 17 projections), MBq

Personalized scan time using a fixed activity (260 MBq), seconds

Relative differencea in activity or scan time compared to clinical practice (260 MBq or 20 s per projection angle, respectively), %

45

85

7

− 67

70

159

12

− 39

100

260

20

0

120

338

26

+ 30

150

462

36

+ 78

  1. aNegative relative differences indicate a reduction in activity or scan time, whereas positive relative differences indicate increased activity or scan time