Skip to main content

Table 5 Lesion-level analysis with decreasing acquisition time

From: Detection of prostate cancer bone metastases with fast whole-body 99mTc-HMDP SPECT/CT using a general-purpose CZT system

 

Acquisition time (min)

Number of positive lesions reported

Number of true positive lesions

Number of false positive lesions

Number of false negative lesions

Number of equivocal lesions reported

Ratio of equivocal to all detected lesions (%)

Reader A

50

52

49

3

51

11

17

32

40

36

4

64

14

26

26

37

35

2

65

17

31

16

49

43

6

57

26

35

Reader B

50

55

52

3

48

7

11

32

54

53

1

47

5

8

26

51

49

2

51

3

6

16

52

50

2

50

4

7

Total

50

107

101

6

99

18

14

32

93

89

5

111

19

17

26

88

84

4

116

20

19

16

101

93

8

107

30

23