Skip to main content

Table 2 Minimum and maximum Hp(0.07)/A received in both hands for each nurse. Hp(0.07)/A obtained with the CND ring and wrist dosimeters, both worn on the dominant hand, are also shown

From: Occupational radiation exposure assessment during the management of [68Ga]Ga-DOTA-TOC

Nurse

CND (D) (µSv/GBq)

Gloves

ND (µSv/GBq)

D (µSv/GBq)

LDL (µSv)

Ring

Wrist

Min

Max

Most exposed

Min

Max

Most exposed

Nurse 1

117

848

6427

a

277

966

B

212

Nurse 2

228

76

562

2556

b

199

261

B

212

Nurse 3

474

273

780

3468

b

643

3419

B

212

Nurse 4

90

761

7055

b

< LDL

427

B

277

Nurse 5

250

710

2107

a

291

677

C

277

Nurse 6

400

789

2539

a

 < LDL

709

C

92

  1. Unknown values (–) are shown when the dosimeters recorded < 0.1 mSv, so it is not possible to normalize their value to the total activity handled