Table 2 Absorbed dosea (Gy) to the nucleus of a single cell for different distributions of 177Lu and 161Tb

From: Radiation doses from 161Tb and 177Lu in single tumour cells and micrometastases

 Cell surfaceIntracytoplasmicWhole cellIntranuclear
177Lu1.93.05.810.7
161Tb5.08.319.538.6
Enhancement factor 161Tb/177Lu2.62.83.43.6
  1. aThe absorbed doses computed with CELLDOSE correspond to a total electron energy release of 1436 MeV from one of the specific regions of interest of a cell of 14 μm diameter and 10 μm diameter nucleus