Volume 2 Supplement 1

Proceedings of the 4th PSMR Conference on PET/MR and SPECT/MR

Open Access

Rapid workflow of mMR PET list-mode data processing using CUDA

  • Pawel Markiewicz1,
  • Kris Thielemans2,
  • David Atkinson1,
  • Simon Arridge1,
  • Brian Hutton2 and
  • Sebastien Ourselin1
EJNMMI Physics20152(Suppl 1):A42

https://doi.org/10.1186/2197-7364-2-S1-A42

Published: 18 May 2015

The purpose of this work is to provide a software solution which would enable very fast list-mode data processing offered by the massively parallel graphics processor units (GPU) while dealing efficiently with the common bottleneck of data transfers between hard disk storage, host (CPU) memory and device (GPU) memory. This software is dedicated to the PETLINK™ list-mode data format which is used by the Siemens’ hybrid Biograph Molecular MR (mMR) scanner. This software is developed as part of our platform for mMR 3D and 4D PET image reconstruction and will be freely accessible to the community. The aim is to perform real time processing (i.e. without perceivable delay) of the list-mode data during data transfers from hard disk to the CPU memory. The output of the processing includes: (1) The count-rate data (head curve: prompts, randoms and singles per second). (2) Plot of the variation of the centre of mass due to kinetics and motion (crude motion detection and quantification). (3) Projection movies (sagittal and coronal) for visual inspection for motion and data quality. (4) Crystal fan-sums for any time frame (used for randoms noise reduction). (5) Singles rate for each detector bucket (used for dead-time correction during normalisation). (6) Static and dynamic sinograms of span-1 and span-11. This workflow enables list-mode data processing synchronously with data transfer from disk to CPU memory. It opens a way for fast creation of multiple bootstrap realisations and multiple image reconstructions for a single dataset providing valuable insight into distributions of any statistic used in the development of robust image bio-markers. Also, the proposed workflow is advantageous for list-mode image reconstruction.

Authors’ Affiliations

(1)
University College London, Centre for Medical Image Computing, Translational Imaging Group
(2)
University College London, Institute of Nuclear Medicine

Copyright

© Markiewicz et al; licensee Springer. 2015

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.