Skip to main content

Articles

Page 5 of 9

  1. The purpose of this study was to evaluate the utility of bellows-based respiratory compensation and navigated hepatobiliary phase imaging to correct for respiratory motion in the setting of dedicated liver PET...

    Authors: Thomas A. Hope, Emily F. Verdin, Emily K. Bergsland, Michael A. Ohliger, Carlos U. Corvera and Eric K. Nakakura

    Citation: EJNMMI Physics 2015 2:21

    Content type: Original research

    Published on:

  2. Advances in gamma camera technology and the emergence of a number of new theranostic radiopharmaceutical pairings have re-awakened interest in in vivo quantification with single-photon-emitting radionuclides. ...

    Authors: Dale L. Bailey, Thomas M. Hennessy, Kathy P. Willowson, E. Courtney Henry, David L.H. Chan, Alireza Aslani and Paul J. Roach

    Citation: EJNMMI Physics 2015 2:20

    Content type: Original research

    Published on:

  3. Non-uniformity influences the interpretation of nuclear medicine based images and consequently their use in treatment planning and monitoring. However, no standardised method for evaluating and ranking heterog...

    Authors: Jonas Grafström, Hanna-Stina Ahlzén and Sharon Stone-Elander

    Citation: EJNMMI Physics 2015 2:19

    Content type: Original research

    Published on:

  4. In integrated PET/MR hybrid imaging the evaluation of PET performance characteristics according to the NEMA standard NU 2–2007 is challenging because of incomplete MR-based attenuation correction (AC) for phan...

    Authors: Susanne Ziegler, Bjoern W. Jakoby, Harald Braun, Daniel H. Paulus and Harald H. Quick

    Citation: EJNMMI Physics 2015 2:18

    Content type: Original research

    Published on:

  5. Generally, attenuation correction is made by incorporating a linear attenuation coefficient, which is based on the attenuation coefficient map (mu-map) created from a computed tomography scan, into the ordered...

    Authors: Yuya Nakamura, Seiji Tomiguchi and Masayuki Tanaka

    Citation: EJNMMI Physics 2015 2:17

    Content type: Original research article

    Published on:

  6. To assess differences between four different voxel-based dosimetry methods (VBDM) for tumor, liver, and lung absorbed doses following 90Y microsphere selective internal radiation therapy (SIRT) based on 90Y brems...

    Authors: Justin K Mikell, Armeen Mahvash, Wendy Siman, Firas Mourtada and S Cheenu Kappadath

    Citation: EJNMMI Physics 2015 2:16

    Content type: OriginalPaper

    Published on:

  7. Image registration algorithms are frequently used to align the reconstructed brain PET frames to remove subject head motion. However, in occupancy studies, this is a challenging task where competitive binding ...

    Authors: Jieqing Jiao, Graham E. Searle, Julia A. Schnabel and Roger N. Gunn

    Citation: EJNMMI Physics 2015 2:15

    Content type: Original research

    Published on:

  8. We present a study performing motion correction (MC) of PET using MR navigators sampled between other protocolled MR sequences during simultaneous PET/MR brain scanning with the purpose of evaluating its clini...

    Authors: Sune H Keller, Casper Hansen, Christian Hansen, Flemming L Andersen, Claes Ladefoged, Claus Svarer, Andreas Kjær, Liselotte Højgaard, Ian Law, Otto M Henriksen and Adam E Hansen

    Citation: EJNMMI Physics 2015 2:14

    Content type: Short communication

    Published on:

    The Erratum to this article has been published in EJNMMI Physics 2015 2:23

  9. Positron Emission Tomography (PET)-based automatic segmentation (PET-AS) methods can improve tumour delineation for radiotherapy treatment planning, particularly for Head and Neck (H&N) cancer. Thorough valida...

    Authors: B Berthon, C Marshall, R Holmes and E Spezi

    Citation: EJNMMI Physics 2015 2:13

    Content type: OriginalPaper

    Published on:

  10. Cerebral blood flow (CBF), oxygen extraction fraction (OEF), and cerebral metabolic rate of oxygen (CMRO2) images have facilitated understanding of the pathophysiological basis of cerebrovascular disorders. Such ...

    Authors: Yukito Maeda, Nobuyuki Kudomi, Yasuhiro Sasakawa, Toshihide Monden, Koji Kato, Yuka Yamamoto, Nobuyuki Kawai and Yoshihiro Nishiyama

    Citation: EJNMMI Physics 2015 2:12

    Content type: Original research

    Published on:

  11. Authors: Charalmpos Tsoukalas, Gautier Laurent, Gloria Jiménez Sánchez, Theodoros Tsotakos, Rana Bazzi, Dimitris Stellas, Constantinos Anagnostopoulos, Lia Moulopoulos, Vasilis Koutoulidis, Maria Paravatou-Petsotas, Stavros Xanthopoulos, Stephane Roux and Penelope Bouziotis

    Citation: EJNMMI Physics 2015 2(Suppl 1):A89

    Content type: Meeting abstract

    Published on:

    This article is part of a Supplement: Volume 2 Supplement 1

  12. Authors: Susanne Passow, Karsten Specht, Tom Christian Adamsen, Martin Biermann, Njål Brekke, Alexander Richard Craven, Lars Ersland, Renate Grüner, Nina Kleven-Madsen, Ole-Heine Kvernenes, Thomas Schwarzlmüller, Rasmus Olesen and Kenneth Hugdahl

    Citation: EJNMMI Physics 2015 2(Suppl 1):A78

    Content type: Meeting abstract

    Published on:

    This article is part of a Supplement: Volume 2 Supplement 1

Affiliated with