Skip to main content

Table 1 Computation times of methods used in phantom experiment

From: Effect of data conserving respiratory motion compensation on left ventricular functional parameters assessed in gated myocardial perfusion SPECT

Method

Time (s)

OSEM

1466.46

RBM-OSEM

2645.79

JMC-OSEM

18,351.60

  1. These reconstructions were performed on Dell Precision T7400 (Intel(R) Xeon(R) CPU E5410 @ 2.33 GHz and 32 GB DDR2 FB-DIMM)