Skip to main content

Table 3 Mean absorbed dose (Gy/GBq) per target location of all patients

From: A head-to-head comparison between two commercial software packages for hybrid dosimetry after peptide receptor radionuclide therapy

 

Mono-exponential

Bi-exponential

Kidneys

Red marrow

Kidneys

Red marrow

Patient

O/E

PD

O/E

PD

O/E

PD

O/E

PD

1

0.61

0.62

0.063

0.015

0.61

0.62

0.095

0.008

2

0.37

0.29

0.088

0.005

0.37

0.30

0.098

0.004

3

0.31

0.43

0.067

0.022

0.44

0.44

0.115

0.007

4

0.24

0.33

0.048

0.015

0.32

0.27

0.094

0.007

5

0.22

0.16

0.063

0.012

0.22

0.19

0.010

0.007

6

1.30

0.74

0.060

0.017

0.30

0.74

0.095

0.009

7

0.44

0.49

0.081

0.015

0.56

0.52

0.117

0.008

8

0.38

0.52

0.058

0.015

0.40

0.58

0.094

0.007

9

0.62

0.61

0.064

0.017

0.62

0.66

0.068

0.008

10

0.44

0.50

0.040

0.030

0.55

0.50

0.082

0.015

  1. O/E OLINDA/EXM; PD PLANET Dose
  2. This patient had one visible kidney on planar imaging