Skip to main content

Table 2 Ambient dose rates recorded with the Atomtex near the vial, at 0.5 m of the chest of the patient and behind the lead screen at three different time points: administration (Admin.), the change in the infusion rate (IR) and the end of administration (End)

From: Radiation exposure assessment of nuclear medicine staff administering [177Lu]Lu-DOTA-TATE with active and passive dosimetry

Protocol

Step

Initial activity (MBq)

Time stamp (min)

Dose rate (µSv/h)

Vial

Patient

Screen

1 (5 sessions)

Admin

7130 ± 99

0

2320 [1930–3100]

37 [23–124]

0.5 [0.3–0.9]

IR

30

138 [103–235]

410 [30–510]

0.4 [0.4–0.5]

End

45

20 [9–31]

600 [50–680]

0.4 [0.3–0.5]

2 (7 sessions)

Admin

7120 ± 63

0

1960 [1690–2200]

48 [20–86]

0.4 [0.3–1.1]

IR

5

1300 [370–1400]

184 [50–940]

0.4 [0.3–1.0]

End

30

35 [16–102]

580 [430–670]

0.3 [0.3–0.4]

  1. The results are divided by protocol