Skip to main content

Table 1 Summary of the number of sessions recorded in this study with cumulative (passive) and real-time (active) dosimetry. Each set corresponds to the dosimetry equipment used in passive dosimetry

From: Radiation exposure assessment of nuclear medicine staff administering [177Lu]Lu-DOTA-TATE with active and passive dosimetry

 

Passive dosimetry

Active dosimetry

Apron

Staff

Set

Sessions (Protocol)*

Total activity (GBq)

Sessions (Protocol)*

Total activity (GBq)

P1

2 (1)

14.7

No

#1

4 (1)

28.9

12 (1)

85.7

Yes

#2

4 (1)

28.3

7 (2)

49.8

#3

4 (1)

28.6

#4

7 (2)

49.8

P2

#1

5 (1)

35.7

5 (1)

35.7

Yes

#2

4 (2)

27.6

5 (2)

34.9

N1

3 (1)

21.7

No

#1

4 (1)

28.9

4 (1)

28.9

Yes

#2

4 (2)

28.3

4 (2)

28.3

N2

#1

2 (1)

14.1

2 (1)

14.1

Yes

N3

#1

9 (1)

64.3

9 (1)

64.3

Yes

#2

6 (2)

42.3

7 (2)

49.6

N4

2 (1)

14.2

Yes

  1. *Protocols refer to the two different ways of administration using the gravity infusion method: Protocol 1 starts the infusion rate at 100 ml/h (30 min) and increases to 200 ml/h (15 min), while Protocol 2 starts at 100 ml/h (5 min) and increases to 400 ml/h (20 min)
  2. The apron corresponds to a 0.5 mm lead equivalent apron