Table 4 Performance of the deep learning derived pSUVR-values to determine amyloid read status using a SUVR threshold of 1.35

From: Estimation of brain amyloid accumulation using deep learning in clinical [11C]PiB PET imaging

 

PET/CT

PET/MRI

Hold-out test n = 300

Hold-out test n = 100

Cohen’s kappa

0.94

0.96

Accuracy

97%

98%

Sensitivity

98%

98%

Specificity

97%

98%

F1-score

98%

98%